Products And Solutions

+
  • undefined

DC Split-type Charging Stack Rectifier Cabinet SSAD


Product Overview:

Rectifier Cabinet is a cabinet-type device for centralized power conversion, with a rated power range of 320kW to 960kW. It does not connect directly to vehicles and serves as a backend energy center.


Contact Mailbox:sales@hnsanshen.com

Product Details

Sasen DC Split-type Charging Stack is an innovative solution for charging stations. It separates high-power rectifier cabinets from the distributed charging terminals. Through an intelligent control system, it dynamically and flexibly allocates the total power of one or more rectifier cabinets to all vehicles currently charging.  

 

Rectifier Cabinet is a cabinet-type device that centrally converts electrical energy. It integrates multiple charging modules inside, specifically responsible for converting the grid's AC power into the DC power required by electric vehicles, and for building a shared "power pool." It does not connect directly to vehicles but acts as a backend energy center, receiving system commands and supplying power to the various front-end charging terminals.

 

Model SSDC240K-SL-7P-4 SSDC320K-SL-7P-4 SSDC360K-SL-7P-6 SSDC480K-SL-7P-6 SSDC480K-SL-7P-8 SSDC640K-SL-7P-8 SSDC600K-SL-7P-10 SSDC800K-SL-7P-10 SSDC720K-SL-7P-12 SSDC960K-SL-7P-12
Rated Power 240kW 320kW 360kW 480kW 480kW 640kW 600kW 800kW 720kW 960kW
Output Circuit 4-channel 4-channel 6-channel 6-channel 8-channel 8-channel 10-channel 10-channel 12-channel 12-channel
Molded Case Circuit Breaker 500A 630A 250A+500A 2*500A 2*500A 2*500A+325A 2*500A+250A 2*500A+630A 3*500A 3*630A
Input Circuit 1-channel 1-channel 2-channel 2-channel 2-channel 3-channel 3-channel 3-channel 3-channel 3-channel
Dimensions (L*W*H) 1800*800*1782(mm) 1912*800*1800(mm)
Input Voltage AC380V+20%
Input Frequency 50Hz±10%
Output Voltage Range 200~1000VDC
Maximum Output Current per Channel 250A
Constant Power Output Voltage Range DC300-500V,DC600-1000V
Efficiency ≥95%(50%-100% of rated output power)
Power Factor ≥0.99(50%-100% of rated output power)
Voltage Regulation Accuracy ≤±0.5%
Current Regulation Accuracy ≤±1%(20%~100% of rated output power)
Current Sharing Imbalance ≤±5%
Ripple Peak-to-Peak Value ≤1%
Protection Class IP54
Operating Environment Indoor/Outdoor
Noise ≤65dB
Heat Dissipation Method Forced air cooling
ITHD ≤5%(50%-100% of rated output power)
Communication Method with Terminal Cabinet CAN communication
Operating Temperature -20℃~+50℃
Relative Humidity 5%~95%
Altitude ≤2000m
Installation Method Floor installation

Recommend Products


Online Consultation


Online Consultation

Online Consultation


To provide you with quality products and services.