Products And Solutions

+
  • undefined

120kW DC Charging Pile SSDC-SF


Product Overview:

Compatible with multiple platforms and requiring no debugging, they come in 60kW, 80kW, and 120kW models, ideal for bus stations, logistics parks, and centralized charging sites.

Category:


Contact Mailbox:sales@hnsanshen.com

Product Details

The Sasen SSDC-SF series charging piles are safe and reliable with IP54 protection and protections against over-temperature, over-voltage, etc. They fit 99% of national standard electric vehicles. Compatible with multiple platforms and requiring no debugging, they come in 60kW, 80kW, and 120kW models, ideal for bus stations, logistics parks, and centralized charging sites.

 

Model SSDC60K-SF-7P-2 SSDC80K-SF-7P-2 SSDC120K-SF-7P-2
Rated Power 60kW 80kw 120kW
Weight About 210kg About 220kg About 240kg
Design Standard GB/T 18487, GB/T 20234
Cable Length 4.5m (standard configuration)
Number of Guns Single/Dual Guns
Body Dimensions 710*385*1500mm(L*W*H)
Display 7-inch LCD touchscreen + LED / 10-inch LCD touchscreen + LED
Networking Ethernet, 4G (optional)
Charging Mode Automatic charging, charging by time, battery level, or amount
Start-up Method Card swiping and QR code scanning (APP, WeChat mini-program, official account, etc.)
Protection Functions Gun temperature detection, short circuit, over-temperature, over-current, leakage, over/under voltage protection, and lightning protection
Charging Method Full-power charging and AB equalization charging
Cloud Platform Supports Cloud Fast Charging, Weijing Cloud, Sanshen Cloud, Ruixiang Cloud, Dak Cloud, and eCharge.
Input Voltage AC380V±20%
Input Frequency 50HZ±10%
Output Voltage Range DC150-1000V
Constant Power Output Voltage Range DC300-1000V
Maximum Output Current per Gun 200A 250A
Output Voltage Accuracy ≤±0.5%
Output Current Accuracy ≤±1%
Voltage Regulation Accuracy ≤±0.5%
Current Regulation Accuracy ≤±1%
Harmonic Content ≤5%
Power Factor ≥0.99 (above 50% load)
Maximum Efficiency ≥95%
Energy Metering Grade 1.0, conforming to GB standards
Insulation Resistance ≥20MQ
Noise ≤65dB
Protection Rating IP54
Operating Environment Indoor or outdoor
Cooling Method Air-cooled
Operating Temperature -20℃~+50℃
Storage Temperature -40℃~+70℃
Relative Humidity 5%-95% non-condensing
Altitude ≤2000m
Auxiliary Power Supply 12V
Installation Method Floor installation

Recommend Products


Online Consultation


Online Consultation

Online Consultation


To provide you with quality products and services.